refactor: reorganize the package into twelve domain subpackages (3.2) (#162)
* refactor: private core to _internal, module-path shims, _plot skeleton (C1)
Foundation of the 3.2 package reorganization:
- _validation/_types/_warnings/_levels_math/utils move (git mv) into the
private phonometry/_internal/ package; ~90 import sites retargeted.
- New phonometry/_compat.py: dynamic sys.modules shims keep every moved
public module path importable for one deprecation cycle (silent import,
DeprecationWarning on attribute access); generalizes and absorbs the
former loudness.py PEP 562 shim (its 3.1 wording preserved).
- _plotting.py moves (git mv) to phonometry/_plot/common.py; a silent
explicit re-export shim keeps the old private path and the 84 lazy
.plot() call sites working until each domain retargets them.
- _warn_renamed gains a 'since' parameter (3.2 for the package moves).
- tests: new test_package_architecture.py (ast edge whitelist +
fresh-interpreter subpackage imports); test_deprecated_aliases gains the
frozen 85-path pre-move snapshot and the _MOVED shim behavior test;
pytest pythonpath=tests for the upcoming mirrored test tree.
- .git-blame-ignore-revs scaffold (hashes appended at the end of Phase 1).
* refactor: metrology subpackage (C2)
core, filter_design, frequencies, parametric_filters, levels, calibration,
compliance and uncertainty move (git mv) into phonometry/metrology/ with a
curated re-export __init__; the flat API and the old module paths keep
working (facade re-exports + _compat shims). Uncertainty renderers carve out
of _plot/common.py into _plot/metrology.py; the 14 metrology test files move
to tests/metrology/ and deep imports across tests/scripts point at the new
canonical paths.
* refactor: psychoacoustics subpackage (C3)
The thirteen psychoacoustics modules (Zwicker/ECMA/Moore-Glasberg loudness,
contours, sharpness, tonality, roughness, fluctuation strength, annoyance,
tonal audibility, private Zwicker tables) move into
phonometry/psychoacoustics/; renderers carve into _plot/psychoacoustics.py;
twelve test files move to tests/psychoacoustics/. The phonometry.loudness
alias now resolves to the relocated canonical module in a single hop.
* refactor: hearing and emission subpackages (C4+C5)
hearing/ gains threshold (renamed from hearing.py), noise-induced hearing
loss, occupational exposure, SII and STI; emission/ gains the ISO 3740
sound-power family, ISO 9614 intensity and ISO/TS 7849 vibration-based
power. Renderers carve into _plot/hearing.py and _plot/emission.py; the
eleven domain test files move under tests/hearing/ and tests/emission/.
* refactor: materials, room and building subpackages (C6-C8)
materials/ collects ISO 354/11654/12999-2 absorption, scattering-diffusion,
road absorption, impedance tube, airflow resistance and EN 29052-1 dynamic
stiffness; room/ the room-acoustics, impulse-response, open-plan, room-noise,
reverberation-prediction and EN 12354-6 modules; building/ the eleven-module
EN 12354 / ISO 717 / ISO 16283 insulation family with EN 15657 and
EN 12354-5 structure-borne sound. Renderers carve into the matching _plot
modules; twenty-six test files move under their domain directories.
* fix: complete the building plot TYPE_CHECKING imports (C8 follow-up)
* refactor: vibration and environmental subpackages (C9+C10)
vibration/ collects human vibration (ISO 8041-1/2631/5349), multiple-shock
(ISO 2631-5), mechanical mobility (ISO 7626-1) and transfer stiffness
(ISO 10846); environmental/ collects the renamed rating (Lden/Ldn) and
measurement (ISO 1996-2) modules plus outdoor propagation (ISO 9613-2),
air absorption (ISO 9613-1), wind-turbine noise (IEC 61400-11) and NT
ACOU 112 impulse prominence. Renderers carve into their _plot modules and
ten test files move under the domain directories.
* refactor: aircraft, underwater and electroacoustics subpackages (C11-C13)
aircraft/ collects EPNL, the renamed atmospheric absorption, ECAC Doc 29
airport contours and ECAC Doc 32 rotorcraft hemispheres; underwater/ the
renamed acoustics/propagation/sound_speed modules with ship noise, pile
driving, ambient noise, sonar equation, seabed reflection and the numerical
solvers; electroacoustics/ distortion and frequency response. Renderers
carve into their _plot modules; seventeen test files move under the domain
directories. All twelve domain subpackages are now in place.
* refactor: finalize the 3.2 package reorganization (C14)
- api-reference gains a Namespaces section (the twelve subpackages with
scope and the 'from phonometry import aircraft as air' idiom); README
quick-start notes the namespaces; CHANGELOG records the added namespaces,
the deprecated flat module paths and the pickle note.
- plot_excitation moves from _plot/common.py to _plot/room.py and the
facade imports it from there; _plot/common.py now holds only shared
helpers and infrastructure.
- hearing/ and environmental/ package __init__ re-export the full public
surface of their renamed modules (threshold, rating) so the pre-move
package-path imports stay silent, as promised by the migration contract.
- SonarCloud cpd exclusion follows core.py to metrology/; llms.txt
regenerated; .git-blame-ignore-revs lists the move commits and the local
blame config registers it.
Full suite 2647 passed; conformance 194/194; golden baseline byte-stable;
import time unchanged vs main (1.09 s vs 1.17 s).
* fix: re-export the measurement surface on phonometry.environmental
Subagent-review finding: the generated environmental/__init__.py missed the
ISO 1996-2 measurement module (its facade import block was momentarily
path-corrupted when the subpackage exports were collected), so
phonometry.environmental.assess_tonal_audibility and 15 sibling names
raised AttributeError while every other domain namespace was complete. Adds
the missing re-exports (including EnvironmentalMeasurementWarning on the
domain namespace) and a new architecture invariant test asserting that
every name the facade imports from a domain submodule is reachable on that
subpackage, so this class of gap cannot recur.
* test: forbid absolute self-imports in the architecture check
Review feedback: the ast edge extraction only saw relative imports, so an
absolute 'from phonometry.x import y' inside the package would bypass the
cross-package whitelist. Such imports now fail the architecture test
directly (the codebase has none; relative imports are the convention).
Spanish docs: UNE terminology, decimal commas, localized snippets and theory figures (#365)
* Normalize Spanish docs prose to UNE acoustic terminology
Sweep the Spanish pages for the non-UNE forms "presion sonora",
"potencia sonora" and "intensidad sonora" and normalize the prose to
the wording used by the official Spanish editions of the standards:
"presion acustica" (UNE-EN ISO 16283-2:2016, UNE-EN ISO 10052:2005,
UNE-EN ISO 3746:2011, UNE-ISO 226:2013), "potencia acustica"
(UNE-EN ISO 3746:2011, UNE-EN ISO 4871:2010, UNE-EN ISO 9614-1:2010),
"intensidad acustica" (UNE-EN 61043:1999, UNE-EN ISO 9614-1:2010) and
"nivel de presion acustica de impactos" (UNE-EN ISO 12354-2:2018,
UNE-EN ISO 717-2:2013). 92 replacements across 32 pages, prose only:
code snippets keep the labels they share with the generated figures.
Rename the intensity guide to "Intensidad acustica (p-p)" and the
structure-borne power guide to "Potencia acustica estructural de
equipos (EN 15657)", updating every cross-link text and the theory
anchor intensidad-sonora-iec-61043 accordingly. The API sidebar group
label becomes "Potencia acustica e intensidad" via api_taxonomy.py
with the generated sidebar regenerated.
* Use decimal commas in Spanish docs prose quantities
Sweep every Spanish page for decimal points leaking into prose numbers
and switch them to the comma the locale convention calls for: the
rotorcraft validation prose (fourteen tolerances such as 0,08 dB(A) and
0,5 s), the insulation-prediction worked example (53,6 dB / 53,8 dB),
the tone-audibility Annex E tone (137,3 Hz), the Mackenzie check value
(1550,744 m/s), the EPNL, loudness and absorption fiche descriptions
(98,3 EPNdB; 8,2 sonos and 70,4 fonios; 0,60 y 0,55), the junction
constants table and the third-octave band-edge table in the signal
analysis theory page. Code snippets, inline code, math, clause numbers
and quoted source text keep their points.
* Pass language="es" in Spanish figure-reproduction snippets
The <details> blocks under each localized figure in the Spanish guides
are meant to reproduce the _es variant shown on the page, but 82 of the
one-line result .plot() calls omitted the language="es" argument and
would render English axis labels instead. Add the argument across 33
guides, matching the pattern the intensity field-indicators snippet
already used. The three lab-insulation results whose plot() does not
take a language argument (lab airborne, lab impact and the
element-normalized intensity difference) are left as they were.
* Extend the UNE terminology sweep to sound absorption
Normalize "absorción sonora" to "absorción acústica" across the
Spanish pages (36 occurrences in 14 pages, including the EN 12354-6
guide title and the theory headings), the wording of UNE-EN ISO
3746:2011 and of the equivalent absorption area in UNE-EN ISO
10140-3:2011, UNE-EN ISO 12354-2:2018 and UNE-EN ISO 16283-2:2016, and
the same term the accredited report strings already use. Also restore
the accent in the theory index anchor to the renamed intensity heading,
since heading slugs keep accented characters.
* Theory pages: illustrate each section family with existing result figures
The seven theory pages carried no figures at all. Embed sixteen of the
existing generated figures (light and dark variants, Spanish variants on
the Spanish mirrors) where the concept matches the prose: weighting
curves, time integration and the p-p intensity estimator in the signal
analysis page; equal-loudness contours, the specific-loudness pattern
and the hearing-threshold panels in perception; NC/RC rating, the
Schroeder decay and the ISO 717-1 shifted reference in rooms and
buildings; the Lden profile, ISO 9613-1 absorption and the three sound
power routes in environment and transport; the scattering coefficient
and ISO 11654 rating in materials and surfaces; and the Wk weighting and
the resonator mobility triplet in vibration. Each embed reuses the alt
text of the guide that owns the figure and adds a one-line caption.
Also give the wave-simulation section hub the reading-order paragraph
its siblings already have, linking the closed-form pages the FDTD solver
cross-checks, in both languages.
* Address review findings from the Spanish locale sweeps
Second pass fixes flagged by review: five terminology occurrences the
line-based sweep missed because the noun and adjective were split by a
line wrap or emphasis markup (sound-power, rotorcraft-noise and two
section hubs); six Spanish pages that still embedded the English figure
variant although the _es variant exists (junction-transmission,
aircraft-noise airport contour, miso-coherence,
objective-intelligibility, psychoacoustic-annoyance twice); and 19 more
language="es" arguments on figure-reproduction plot calls the first
pass missed, chained-call receivers such as room.noise_criterion(spl)
.plot() and the axes-creating first call of the two-profile
atmospheric-refraction snippet among them. The lab-insulation plot
wrappers forward keyword arguments to the rating plot, so the three
calls excluded earlier now take the argument too. All Spanish python
fences re-checked to compile and EN/ES parity re-verified.
* Carry the UNE terminology into the generated-asset Spanish strings
Apply the same evidence-based decisions to every Spanish string source
that feeds generated assets: the translation tables of
generate_graphs.py and generate_diagrams.py, the _STRINGS tables of the
plot modules and the report i18n values. 35 strings change: "presión
acústica" (UNE-EN ISO 16283-2:2016, 10052:2005, 3746:2011),
"potencia acústica" (UNE-EN ISO 3746:2011, 4871:2010, 9614-1:2010),
"intensidad acústica" (UNE-EN 61043:1999, 9614-1:2010), "absorción
acústica" (UNE-EN ISO 3746:2011) and "nivel de presión acústica de
impactos" (UNE-EN ISO 12354-2:2018). Strings the UNE editions keep are
untouched: "emisión sonora", "exposición sonora", "campo sonoro",
"fuente sonora". Only Spanish values change; the English keys stay.
The two plot-i18n test assertions that pin the axis label follow, and
the eight Spanish doc fences that deliberately mirrored the old figure
labels now mirror the new ones.
* Regenerate the Spanish figure variants with the UNE terminology
make graphs after the string-source change: 48 files, all of them _es
or _es_dark variants (24 figure/diagram pairs), picking up "presión
acústica", "potencia acústica", "intensidad acústica", "absorción
acústica" and "nivel de presión acústica de impactos" in titles and
axis labels. The English variants are untouched. The committed example
fiches need no regeneration: every example in generate_reports.py
renders in English, so no changed Spanish report string reaches them.
* Align the intensity-fiche Spanish assertions with the UNE terminology
Spanish docs: UNE terminology, decimal commas, localized snippets and theory figures (#365)
* Normalize Spanish docs prose to UNE acoustic terminology
Sweep the Spanish pages for the non-UNE forms "presion sonora",
"potencia sonora" and "intensidad sonora" and normalize the prose to
the wording used by the official Spanish editions of the standards:
"presion acustica" (UNE-EN ISO 16283-2:2016, UNE-EN ISO 10052:2005,
UNE-EN ISO 3746:2011, UNE-ISO 226:2013), "potencia acustica"
(UNE-EN ISO 3746:2011, UNE-EN ISO 4871:2010, UNE-EN ISO 9614-1:2010),
"intensidad acustica" (UNE-EN 61043:1999, UNE-EN ISO 9614-1:2010) and
"nivel de presion acustica de impactos" (UNE-EN ISO 12354-2:2018,
UNE-EN ISO 717-2:2013). 92 replacements across 32 pages, prose only:
code snippets keep the labels they share with the generated figures.
Rename the intensity guide to "Intensidad acustica (p-p)" and the
structure-borne power guide to "Potencia acustica estructural de
equipos (EN 15657)", updating every cross-link text and the theory
anchor intensidad-sonora-iec-61043 accordingly. The API sidebar group
label becomes "Potencia acustica e intensidad" via api_taxonomy.py
with the generated sidebar regenerated.
* Use decimal commas in Spanish docs prose quantities
Sweep every Spanish page for decimal points leaking into prose numbers
and switch them to the comma the locale convention calls for: the
rotorcraft validation prose (fourteen tolerances such as 0,08 dB(A) and
0,5 s), the insulation-prediction worked example (53,6 dB / 53,8 dB),
the tone-audibility Annex E tone (137,3 Hz), the Mackenzie check value
(1550,744 m/s), the EPNL, loudness and absorption fiche descriptions
(98,3 EPNdB; 8,2 sonos and 70,4 fonios; 0,60 y 0,55), the junction
constants table and the third-octave band-edge table in the signal
analysis theory page. Code snippets, inline code, math, clause numbers
and quoted source text keep their points.
* Pass language="es" in Spanish figure-reproduction snippets
The <details> blocks under each localized figure in the Spanish guides
are meant to reproduce the _es variant shown on the page, but 82 of the
one-line result .plot() calls omitted the language="es" argument and
would render English axis labels instead. Add the argument across 33
guides, matching the pattern the intensity field-indicators snippet
already used. The three lab-insulation results whose plot() does not
take a language argument (lab airborne, lab impact and the
element-normalized intensity difference) are left as they were.
* Extend the UNE terminology sweep to sound absorption
Normalize "absorción sonora" to "absorción acústica" across the
Spanish pages (36 occurrences in 14 pages, including the EN 12354-6
guide title and the theory headings), the wording of UNE-EN ISO
3746:2011 and of the equivalent absorption area in UNE-EN ISO
10140-3:2011, UNE-EN ISO 12354-2:2018 and UNE-EN ISO 16283-2:2016, and
the same term the accredited report strings already use. Also restore
the accent in the theory index anchor to the renamed intensity heading,
since heading slugs keep accented characters.
* Theory pages: illustrate each section family with existing result figures
The seven theory pages carried no figures at all. Embed sixteen of the
existing generated figures (light and dark variants, Spanish variants on
the Spanish mirrors) where the concept matches the prose: weighting
curves, time integration and the p-p intensity estimator in the signal
analysis page; equal-loudness contours, the specific-loudness pattern
and the hearing-threshold panels in perception; NC/RC rating, the
Schroeder decay and the ISO 717-1 shifted reference in rooms and
buildings; the Lden profile, ISO 9613-1 absorption and the three sound
power routes in environment and transport; the scattering coefficient
and ISO 11654 rating in materials and surfaces; and the Wk weighting and
the resonator mobility triplet in vibration. Each embed reuses the alt
text of the guide that owns the figure and adds a one-line caption.
Also give the wave-simulation section hub the reading-order paragraph
its siblings already have, linking the closed-form pages the FDTD solver
cross-checks, in both languages.
* Address review findings from the Spanish locale sweeps
Second pass fixes flagged by review: five terminology occurrences the
line-based sweep missed because the noun and adjective were split by a
line wrap or emphasis markup (sound-power, rotorcraft-noise and two
section hubs); six Spanish pages that still embedded the English figure
variant although the _es variant exists (junction-transmission,
aircraft-noise airport contour, miso-coherence,
objective-intelligibility, psychoacoustic-annoyance twice); and 19 more
language="es" arguments on figure-reproduction plot calls the first
pass missed, chained-call receivers such as room.noise_criterion(spl)
.plot() and the axes-creating first call of the two-profile
atmospheric-refraction snippet among them. The lab-insulation plot
wrappers forward keyword arguments to the rating plot, so the three
calls excluded earlier now take the argument too. All Spanish python
fences re-checked to compile and EN/ES parity re-verified.
* Carry the UNE terminology into the generated-asset Spanish strings
Apply the same evidence-based decisions to every Spanish string source
that feeds generated assets: the translation tables of
generate_graphs.py and generate_diagrams.py, the _STRINGS tables of the
plot modules and the report i18n values. 35 strings change: "presión
acústica" (UNE-EN ISO 16283-2:2016, 10052:2005, 3746:2011),
"potencia acústica" (UNE-EN ISO 3746:2011, 4871:2010, 9614-1:2010),
"intensidad acústica" (UNE-EN 61043:1999, 9614-1:2010), "absorción
acústica" (UNE-EN ISO 3746:2011) and "nivel de presión acústica de
impactos" (UNE-EN ISO 12354-2:2018). Strings the UNE editions keep are
untouched: "emisión sonora", "exposición sonora", "campo sonoro",
"fuente sonora". Only Spanish values change; the English keys stay.
The two plot-i18n test assertions that pin the axis label follow, and
the eight Spanish doc fences that deliberately mirrored the old figure
labels now mirror the new ones.
* Regenerate the Spanish figure variants with the UNE terminology
make graphs after the string-source change: 48 files, all of them _es
or _es_dark variants (24 figure/diagram pairs), picking up "presión
acústica", "potencia acústica", "intensidad acústica", "absorción
acústica" and "nivel de presión acústica de impactos" in titles and
axis labels. The English variants are untouched. The committed example
fiches need no regeneration: every example in generate_reports.py
renders in English, so no changed Spanish report string reaches them.
* Align the intensity-fiche Spanish assertions with the UNE terminology
Spanish docs: UNE terminology, decimal commas, localized snippets and theory figures (#365)
* Normalize Spanish docs prose to UNE acoustic terminology
Sweep the Spanish pages for the non-UNE forms "presion sonora",
"potencia sonora" and "intensidad sonora" and normalize the prose to
the wording used by the official Spanish editions of the standards:
"presion acustica" (UNE-EN ISO 16283-2:2016, UNE-EN ISO 10052:2005,
UNE-EN ISO 3746:2011, UNE-ISO 226:2013), "potencia acustica"
(UNE-EN ISO 3746:2011, UNE-EN ISO 4871:2010, UNE-EN ISO 9614-1:2010),
"intensidad acustica" (UNE-EN 61043:1999, UNE-EN ISO 9614-1:2010) and
"nivel de presion acustica de impactos" (UNE-EN ISO 12354-2:2018,
UNE-EN ISO 717-2:2013). 92 replacements across 32 pages, prose only:
code snippets keep the labels they share with the generated figures.
Rename the intensity guide to "Intensidad acustica (p-p)" and the
structure-borne power guide to "Potencia acustica estructural de
equipos (EN 15657)", updating every cross-link text and the theory
anchor intensidad-sonora-iec-61043 accordingly. The API sidebar group
label becomes "Potencia acustica e intensidad" via api_taxonomy.py
with the generated sidebar regenerated.
* Use decimal commas in Spanish docs prose quantities
Sweep every Spanish page for decimal points leaking into prose numbers
and switch them to the comma the locale convention calls for: the
rotorcraft validation prose (fourteen tolerances such as 0,08 dB(A) and
0,5 s), the insulation-prediction worked example (53,6 dB / 53,8 dB),
the tone-audibility Annex E tone (137,3 Hz), the Mackenzie check value
(1550,744 m/s), the EPNL, loudness and absorption fiche descriptions
(98,3 EPNdB; 8,2 sonos and 70,4 fonios; 0,60 y 0,55), the junction
constants table and the third-octave band-edge table in the signal
analysis theory page. Code snippets, inline code, math, clause numbers
and quoted source text keep their points.
* Pass language="es" in Spanish figure-reproduction snippets
The <details> blocks under each localized figure in the Spanish guides
are meant to reproduce the _es variant shown on the page, but 82 of the
one-line result .plot() calls omitted the language="es" argument and
would render English axis labels instead. Add the argument across 33
guides, matching the pattern the intensity field-indicators snippet
already used. The three lab-insulation results whose plot() does not
take a language argument (lab airborne, lab impact and the
element-normalized intensity difference) are left as they were.
* Extend the UNE terminology sweep to sound absorption
Normalize "absorción sonora" to "absorción acústica" across the
Spanish pages (36 occurrences in 14 pages, including the EN 12354-6
guide title and the theory headings), the wording of UNE-EN ISO
3746:2011 and of the equivalent absorption area in UNE-EN ISO
10140-3:2011, UNE-EN ISO 12354-2:2018 and UNE-EN ISO 16283-2:2016, and
the same term the accredited report strings already use. Also restore
the accent in the theory index anchor to the renamed intensity heading,
since heading slugs keep accented characters.
* Theory pages: illustrate each section family with existing result figures
The seven theory pages carried no figures at all. Embed sixteen of the
existing generated figures (light and dark variants, Spanish variants on
the Spanish mirrors) where the concept matches the prose: weighting
curves, time integration and the p-p intensity estimator in the signal
analysis page; equal-loudness contours, the specific-loudness pattern
and the hearing-threshold panels in perception; NC/RC rating, the
Schroeder decay and the ISO 717-1 shifted reference in rooms and
buildings; the Lden profile, ISO 9613-1 absorption and the three sound
power routes in environment and transport; the scattering coefficient
and ISO 11654 rating in materials and surfaces; and the Wk weighting and
the resonator mobility triplet in vibration. Each embed reuses the alt
text of the guide that owns the figure and adds a one-line caption.
Also give the wave-simulation section hub the reading-order paragraph
its siblings already have, linking the closed-form pages the FDTD solver
cross-checks, in both languages.
* Address review findings from the Spanish locale sweeps
Second pass fixes flagged by review: five terminology occurrences the
line-based sweep missed because the noun and adjective were split by a
line wrap or emphasis markup (sound-power, rotorcraft-noise and two
section hubs); six Spanish pages that still embedded the English figure
variant although the _es variant exists (junction-transmission,
aircraft-noise airport contour, miso-coherence,
objective-intelligibility, psychoacoustic-annoyance twice); and 19 more
language="es" arguments on figure-reproduction plot calls the first
pass missed, chained-call receivers such as room.noise_criterion(spl)
.plot() and the axes-creating first call of the two-profile
atmospheric-refraction snippet among them. The lab-insulation plot
wrappers forward keyword arguments to the rating plot, so the three
calls excluded earlier now take the argument too. All Spanish python
fences re-checked to compile and EN/ES parity re-verified.
* Carry the UNE terminology into the generated-asset Spanish strings
Apply the same evidence-based decisions to every Spanish string source
that feeds generated assets: the translation tables of
generate_graphs.py and generate_diagrams.py, the _STRINGS tables of the
plot modules and the report i18n values. 35 strings change: "presión
acústica" (UNE-EN ISO 16283-2:2016, 10052:2005, 3746:2011),
"potencia acústica" (UNE-EN ISO 3746:2011, 4871:2010, 9614-1:2010),
"intensidad acústica" (UNE-EN 61043:1999, 9614-1:2010), "absorción
acústica" (UNE-EN ISO 3746:2011) and "nivel de presión acústica de
impactos" (UNE-EN ISO 12354-2:2018). Strings the UNE editions keep are
untouched: "emisión sonora", "exposición sonora", "campo sonoro",
"fuente sonora". Only Spanish values change; the English keys stay.
The two plot-i18n test assertions that pin the axis label follow, and
the eight Spanish doc fences that deliberately mirrored the old figure
labels now mirror the new ones.
* Regenerate the Spanish figure variants with the UNE terminology
make graphs after the string-source change: 48 files, all of them _es
or _es_dark variants (24 figure/diagram pairs), picking up "presión
acústica", "potencia acústica", "intensidad acústica", "absorción
acústica" and "nivel de presión acústica de impactos" in titles and
axis labels. The English variants are untouched. The committed example
fiches need no regeneration: every example in generate_reports.py
renders in English, so no changed Spanish report string reaches them.
* Align the intensity-fiche Spanish assertions with the UNE terminology
Metadiffusers: deep-subwavelength Schroeder diffusers (#397)
* Metadiffusers: deep-subwavelength Schroeder diffusers
A new materials module models the slotted panels of Jimenez, Cox,
Romero-Garcia and Groby (Sci. Rep. 7:5389, 2017): thin slits loaded by
Helmholtz resonators whose slow sound pulls the quarter-wavelength
condition of each well into the deep-subwavelength regime, so a
centimetres-thick panel reproduces the reflection-phase profile of a
Schroeder diffuser tens of centimetres deep, and critically coupled
slits provide the perfectly absorbing state of ternary sequences.
The per-well chain reuses the slow-sound absorber transfer matrix,
extended with the paper's two-dimensional resonator model: slit-geometry
visco-thermal effective parameters for necks and cavities and the 2-D
end-correction fits (0.41 w_n polynomials), selected by a new
resonator_geometry switch that keeps the square-duct model as default
elsewhere. metadiffuser_reflection returns the per-well complex R_n(f),
and metadiffuser_polar_response / metadiffuser_diffusion_spectrum reduce
it through the bare Fraunhofer far field of the paper (no obliquity
factor) to the ISO 17497-2 directional and normalized coefficients.
The tests pin the implementation to the published designs: the first
slit of the quadratic-residue panel reaches critical coupling at the
printed 2270 Hz within 1.6 %, its reflection matches the target QRD at
the 2 kHz evaluation to under 4 degrees per well, the ternary perfect
absorber peaks at alpha = 0.999 at 502 Hz, the primitive-root panel
shows its sharp slit resonance at 1505 Hz and a -19 dB specular notch,
and the diffusion coefficients of the supplementary land inside soft
bounds. Necks wider than their slit fall outside the fitted domain of
the Dubos correction and now raise a warning (the broadband Table 4
design does this by construction, so only its mid-band diffusion is
pinned).
The surface-scattering guide gains a metadiffuser section with the
published five-slit panel as a runnable example, a to-scale panel
drawing (MetadiffuserResult.plot_geometry) and a polar overlay showing
the 2 cm panel scattering like the 27.4 cm QRD it mimics.
* Metadiffuser FDTD clip: three panels meshed at 0.25 mm with GPU-first fields
The clip compares a flat rigid control slab, the 27 cm QRD and the 2 cm
metadiffuser under the same tapered 2 kHz wavefront, all in a free-field
box (sponges on the four sides; the lateral cosine taper keeps the
incident front off the side sponges, so it stays plane and the free-field
reference subtracts exactly). A unit-cell convergence check against the
transfer-matrix phase fixed the mesh at 0.25 mm, where the reflection
phase is converged to under 2 degrees; the fields run on the .env GPU
host through the fdtd_gpu runner when it answers, with a three-worker
CPU pool as the fallback.
* Address review: QRD clip loop restored, docstrings, dedup rows, plot smoke tests
The three-column edit had also widened the panel loop of the original
animate_fdtd_diffusion, which would crash its next render; the loop is
back to two panels and the function is again identical to main. The
Table-1 rows are hoisted into one shared constant, the trail reference
is guarded against a silent zero, the GPU history is preallocated, the
metadiffuser docstrings document resonator_geometry and the drawing
orientation, the citation carries the accented author names, and the
new plot renderers gained smoke tests in both languages (the SonarCloud
coverage gap) together with the hoisted constructions and helper
extractions the analysis asked for.
* Address review: regenerate the API page and hoist the last raises construction
Perception, hearing and speech guides: result figures and when-to-use prose (#361)
* Perception, hearing and speech guides: result figures and when-to-use prose
Add ToneAssessment.plot(), which draws an ECMA-418-1 tone against the
prominence criterion of its own method (recovered from criterion_db) over the
whole range of interest, with the deciding margin marked, and a
view="levels" option on ToneAudibilityResult.plot() that exposes the
level-versus-frequency view the ISO 1996-2 fiche already embedded.
Add eleven single-concept figures to the perception, hearing and speech
guides, each a realistic result drawn by its own .plot(): the tone prominence
verdict, the ISO/PAS 20065 tone levels, the ISO/PAS 1996-3 onset detection,
the ISO 532-2 specific loudness, the ECMA-418-2 specific tonality, the
specific fluctuation strength, the SII band audibility under a hearing loss,
the ISO 7029 fractile band, the ISO 1999 NIPTS audiogram, the STOI per-band
correlation and the IEC 60268-16 per-band MTI. Every figure is embedded in
the English guide, the Spanish mirror and the docs mirror with the dual
snippet block, and every plottable snippet on those pages now names its
.plot().
Prose: the tone-prominence guide gains a comparison of the four tonality
assessments the library implements and when each applies, the
hearing-threshold guide explains how the ISO 7029 fractiles feed the ISO 1999
age component and gains a See-also section, and the objective-intelligibility
guide gains the "which measure, and when" section that existed only in the
docs mirror, extended with the STOI/ESTOI, STI and SII choice.
Also label the STOI band axis at whole-hertz resolution and let the shaded
critical band of the tone-audibility levels plot follow the figure
background, so it reads on the white report page and on dark figures alike.
* Correct two figure alt texts against the plotted values
The ISO 7029 fractile figure describes the median and the 90 % fractile with
the values it actually draws (10 to 50 dB and 22 to 74 dB), and the
ECMA-418-2 specific tonality peak is at 9 Bark_HMS.
Metadiffusers: deep-subwavelength Schroeder diffusers (#397)
* Metadiffusers: deep-subwavelength Schroeder diffusers
A new materials module models the slotted panels of Jimenez, Cox,
Romero-Garcia and Groby (Sci. Rep. 7:5389, 2017): thin slits loaded by
Helmholtz resonators whose slow sound pulls the quarter-wavelength
condition of each well into the deep-subwavelength regime, so a
centimetres-thick panel reproduces the reflection-phase profile of a
Schroeder diffuser tens of centimetres deep, and critically coupled
slits provide the perfectly absorbing state of ternary sequences.
The per-well chain reuses the slow-sound absorber transfer matrix,
extended with the paper's two-dimensional resonator model: slit-geometry
visco-thermal effective parameters for necks and cavities and the 2-D
end-correction fits (0.41 w_n polynomials), selected by a new
resonator_geometry switch that keeps the square-duct model as default
elsewhere. metadiffuser_reflection returns the per-well complex R_n(f),
and metadiffuser_polar_response / metadiffuser_diffusion_spectrum reduce
it through the bare Fraunhofer far field of the paper (no obliquity
factor) to the ISO 17497-2 directional and normalized coefficients.
The tests pin the implementation to the published designs: the first
slit of the quadratic-residue panel reaches critical coupling at the
printed 2270 Hz within 1.6 %, its reflection matches the target QRD at
the 2 kHz evaluation to under 4 degrees per well, the ternary perfect
absorber peaks at alpha = 0.999 at 502 Hz, the primitive-root panel
shows its sharp slit resonance at 1505 Hz and a -19 dB specular notch,
and the diffusion coefficients of the supplementary land inside soft
bounds. Necks wider than their slit fall outside the fitted domain of
the Dubos correction and now raise a warning (the broadband Table 4
design does this by construction, so only its mid-band diffusion is
pinned).
The surface-scattering guide gains a metadiffuser section with the
published five-slit panel as a runnable example, a to-scale panel
drawing (MetadiffuserResult.plot_geometry) and a polar overlay showing
the 2 cm panel scattering like the 27.4 cm QRD it mimics.
* Metadiffuser FDTD clip: three panels meshed at 0.25 mm with GPU-first fields
The clip compares a flat rigid control slab, the 27 cm QRD and the 2 cm
metadiffuser under the same tapered 2 kHz wavefront, all in a free-field
box (sponges on the four sides; the lateral cosine taper keeps the
incident front off the side sponges, so it stays plane and the free-field
reference subtracts exactly). A unit-cell convergence check against the
transfer-matrix phase fixed the mesh at 0.25 mm, where the reflection
phase is converged to under 2 degrees; the fields run on the .env GPU
host through the fdtd_gpu runner when it answers, with a three-worker
CPU pool as the fallback.
* Address review: QRD clip loop restored, docstrings, dedup rows, plot smoke tests
The three-column edit had also widened the panel loop of the original
animate_fdtd_diffusion, which would crash its next render; the loop is
back to two panels and the function is again identical to main. The
Table-1 rows are hoisted into one shared constant, the trail reference
is guarded against a silent zero, the GPU history is preallocated, the
metadiffuser docstrings document resonator_geometry and the drawing
orientation, the citation carries the accented author names, and the
new plot renderers gained smoke tests in both languages (the SonarCloud
coverage gap) together with the hoisted constructions and helper
extractions the analysis asked for.
* Address review: regenerate the API page and hoist the last raises construction
Core metrology guides: result figures, ResampledSignalResult.plot() and real introductions (#364)
* Add ResampledSignalResult.plot(): the delivered anti-alias filter against its design spec
* Rewrite the multichannel guide intro: concrete use cases, per-channel guarantees, Bendat & Piersol citations
* Give the levels page a real introduction: descriptor families, when-to-use guidance and survey references
* Time weighting: framing intro with detector history, ANSI S1.4/Bies references and sibling links
* Calibration: proper introduction (SPL vs dBFS choice, workflow framing) with Bies reference and sibling links
* Add eleven core-metrology figures: resampling spec, cepstrum variants, liftering, correlation, IR alignment, Hilbert envelope, cross-spectra, Golay recovery, TSA noise law, runs test
* Test signals: anti-alias figure with dual snippet, res.plot() mention, See also, docs mirror sync
* Cepstrum guide: variants and liftering figures with dual snippets, complex-cepstrum plot mention
* Correlation guide: normalization, IR-alignment and Hilbert-envelope figures with dual snippets
* Spectral analysis: cross-spectral density and coherent-output-SNR figures with dual snippets
* System measurement: Golay exact-recovery figure and plot mentions for the inversion workflow
* Synchronous averaging: sqrt(N) figure, diagnostics-tool guidance, See also, recording naming
* Data qualification: runs-test figure with dual snippet and peak-statistics plot mention
* MISO coherence: conditioning-order snippet, practical pitfalls and See also across the three trees
* Time-frequency: Harris window reference and See also across the three trees
* GUM uncertainty: map the domain pages that consume the clause-5 machinery, expand See also
* Filter banks: compliance plot mentions and recording naming in the crossover snippet
* Changelog entry for the core-metrology documentation figures and prose
* Regenerate llms-full.txt for the core-metrology documentation
* Drop the duplicated phase-axis translation key
Spanish docs: UNE terminology, decimal commas, localized snippets and theory figures (#365)
* Normalize Spanish docs prose to UNE acoustic terminology
Sweep the Spanish pages for the non-UNE forms "presion sonora",
"potencia sonora" and "intensidad sonora" and normalize the prose to
the wording used by the official Spanish editions of the standards:
"presion acustica" (UNE-EN ISO 16283-2:2016, UNE-EN ISO 10052:2005,
UNE-EN ISO 3746:2011, UNE-ISO 226:2013), "potencia acustica"
(UNE-EN ISO 3746:2011, UNE-EN ISO 4871:2010, UNE-EN ISO 9614-1:2010),
"intensidad acustica" (UNE-EN 61043:1999, UNE-EN ISO 9614-1:2010) and
"nivel de presion acustica de impactos" (UNE-EN ISO 12354-2:2018,
UNE-EN ISO 717-2:2013). 92 replacements across 32 pages, prose only:
code snippets keep the labels they share with the generated figures.
Rename the intensity guide to "Intensidad acustica (p-p)" and the
structure-borne power guide to "Potencia acustica estructural de
equipos (EN 15657)", updating every cross-link text and the theory
anchor intensidad-sonora-iec-61043 accordingly. The API sidebar group
label becomes "Potencia acustica e intensidad" via api_taxonomy.py
with the generated sidebar regenerated.
* Use decimal commas in Spanish docs prose quantities
Sweep every Spanish page for decimal points leaking into prose numbers
and switch them to the comma the locale convention calls for: the
rotorcraft validation prose (fourteen tolerances such as 0,08 dB(A) and
0,5 s), the insulation-prediction worked example (53,6 dB / 53,8 dB),
the tone-audibility Annex E tone (137,3 Hz), the Mackenzie check value
(1550,744 m/s), the EPNL, loudness and absorption fiche descriptions
(98,3 EPNdB; 8,2 sonos and 70,4 fonios; 0,60 y 0,55), the junction
constants table and the third-octave band-edge table in the signal
analysis theory page. Code snippets, inline code, math, clause numbers
and quoted source text keep their points.
* Pass language="es" in Spanish figure-reproduction snippets
The <details> blocks under each localized figure in the Spanish guides
are meant to reproduce the _es variant shown on the page, but 82 of the
one-line result .plot() calls omitted the language="es" argument and
would render English axis labels instead. Add the argument across 33
guides, matching the pattern the intensity field-indicators snippet
already used. The three lab-insulation results whose plot() does not
take a language argument (lab airborne, lab impact and the
element-normalized intensity difference) are left as they were.
* Extend the UNE terminology sweep to sound absorption
Normalize "absorción sonora" to "absorción acústica" across the
Spanish pages (36 occurrences in 14 pages, including the EN 12354-6
guide title and the theory headings), the wording of UNE-EN ISO
3746:2011 and of the equivalent absorption area in UNE-EN ISO
10140-3:2011, UNE-EN ISO 12354-2:2018 and UNE-EN ISO 16283-2:2016, and
the same term the accredited report strings already use. Also restore
the accent in the theory index anchor to the renamed intensity heading,
since heading slugs keep accented characters.
* Theory pages: illustrate each section family with existing result figures
The seven theory pages carried no figures at all. Embed sixteen of the
existing generated figures (light and dark variants, Spanish variants on
the Spanish mirrors) where the concept matches the prose: weighting
curves, time integration and the p-p intensity estimator in the signal
analysis page; equal-loudness contours, the specific-loudness pattern
and the hearing-threshold panels in perception; NC/RC rating, the
Schroeder decay and the ISO 717-1 shifted reference in rooms and
buildings; the Lden profile, ISO 9613-1 absorption and the three sound
power routes in environment and transport; the scattering coefficient
and ISO 11654 rating in materials and surfaces; and the Wk weighting and
the resonator mobility triplet in vibration. Each embed reuses the alt
text of the guide that owns the figure and adds a one-line caption.
Also give the wave-simulation section hub the reading-order paragraph
its siblings already have, linking the closed-form pages the FDTD solver
cross-checks, in both languages.
* Address review findings from the Spanish locale sweeps
Second pass fixes flagged by review: five terminology occurrences the
line-based sweep missed because the noun and adjective were split by a
line wrap or emphasis markup (sound-power, rotorcraft-noise and two
section hubs); six Spanish pages that still embedded the English figure
variant although the _es variant exists (junction-transmission,
aircraft-noise airport contour, miso-coherence,
objective-intelligibility, psychoacoustic-annoyance twice); and 19 more
language="es" arguments on figure-reproduction plot calls the first
pass missed, chained-call receivers such as room.noise_criterion(spl)
.plot() and the axes-creating first call of the two-profile
atmospheric-refraction snippet among them. The lab-insulation plot
wrappers forward keyword arguments to the rating plot, so the three
calls excluded earlier now take the argument too. All Spanish python
fences re-checked to compile and EN/ES parity re-verified.
* Carry the UNE terminology into the generated-asset Spanish strings
Apply the same evidence-based decisions to every Spanish string source
that feeds generated assets: the translation tables of
generate_graphs.py and generate_diagrams.py, the _STRINGS tables of the
plot modules and the report i18n values. 35 strings change: "presión
acústica" (UNE-EN ISO 16283-2:2016, 10052:2005, 3746:2011),
"potencia acústica" (UNE-EN ISO 3746:2011, 4871:2010, 9614-1:2010),
"intensidad acústica" (UNE-EN 61043:1999, 9614-1:2010), "absorción
acústica" (UNE-EN ISO 3746:2011) and "nivel de presión acústica de
impactos" (UNE-EN ISO 12354-2:2018). Strings the UNE editions keep are
untouched: "emisión sonora", "exposición sonora", "campo sonoro",
"fuente sonora". Only Spanish values change; the English keys stay.
The two plot-i18n test assertions that pin the axis label follow, and
the eight Spanish doc fences that deliberately mirrored the old figure
labels now mirror the new ones.
* Regenerate the Spanish figure variants with the UNE terminology
make graphs after the string-source change: 48 files, all of them _es
or _es_dark variants (24 figure/diagram pairs), picking up "presión
acústica", "potencia acústica", "intensidad acústica", "absorción
acústica" and "nivel de presión acústica de impactos" in titles and
axis labels. The English variants are untouched. The committed example
fiches need no regeneration: every example in generate_reports.py
renders in English, so no changed Spanish report string reaches them.
* Align the intensity-fiche Spanish assertions with the UNE terminology
Spanish docs: UNE terminology, decimal commas, localized snippets and theory figures (#365)
* Normalize Spanish docs prose to UNE acoustic terminology
Sweep the Spanish pages for the non-UNE forms "presion sonora",
"potencia sonora" and "intensidad sonora" and normalize the prose to
the wording used by the official Spanish editions of the standards:
"presion acustica" (UNE-EN ISO 16283-2:2016, UNE-EN ISO 10052:2005,
UNE-EN ISO 3746:2011, UNE-ISO 226:2013), "potencia acustica"
(UNE-EN ISO 3746:2011, UNE-EN ISO 4871:2010, UNE-EN ISO 9614-1:2010),
"intensidad acustica" (UNE-EN 61043:1999, UNE-EN ISO 9614-1:2010) and
"nivel de presion acustica de impactos" (UNE-EN ISO 12354-2:2018,
UNE-EN ISO 717-2:2013). 92 replacements across 32 pages, prose only:
code snippets keep the labels they share with the generated figures.
Rename the intensity guide to "Intensidad acustica (p-p)" and the
structure-borne power guide to "Potencia acustica estructural de
equipos (EN 15657)", updating every cross-link text and the theory
anchor intensidad-sonora-iec-61043 accordingly. The API sidebar group
label becomes "Potencia acustica e intensidad" via api_taxonomy.py
with the generated sidebar regenerated.
* Use decimal commas in Spanish docs prose quantities
Sweep every Spanish page for decimal points leaking into prose numbers
and switch them to the comma the locale convention calls for: the
rotorcraft validation prose (fourteen tolerances such as 0,08 dB(A) and
0,5 s), the insulation-prediction worked example (53,6 dB / 53,8 dB),
the tone-audibility Annex E tone (137,3 Hz), the Mackenzie check value
(1550,744 m/s), the EPNL, loudness and absorption fiche descriptions
(98,3 EPNdB; 8,2 sonos and 70,4 fonios; 0,60 y 0,55), the junction
constants table and the third-octave band-edge table in the signal
analysis theory page. Code snippets, inline code, math, clause numbers
and quoted source text keep their points.
* Pass language="es" in Spanish figure-reproduction snippets
The <details> blocks under each localized figure in the Spanish guides
are meant to reproduce the _es variant shown on the page, but 82 of the
one-line result .plot() calls omitted the language="es" argument and
would render English axis labels instead. Add the argument across 33
guides, matching the pattern the intensity field-indicators snippet
already used. The three lab-insulation results whose plot() does not
take a language argument (lab airborne, lab impact and the
element-normalized intensity difference) are left as they were.
* Extend the UNE terminology sweep to sound absorption
Normalize "absorción sonora" to "absorción acústica" across the
Spanish pages (36 occurrences in 14 pages, including the EN 12354-6
guide title and the theory headings), the wording of UNE-EN ISO
3746:2011 and of the equivalent absorption area in UNE-EN ISO
10140-3:2011, UNE-EN ISO 12354-2:2018 and UNE-EN ISO 16283-2:2016, and
the same term the accredited report strings already use. Also restore
the accent in the theory index anchor to the renamed intensity heading,
since heading slugs keep accented characters.
* Theory pages: illustrate each section family with existing result figures
The seven theory pages carried no figures at all. Embed sixteen of the
existing generated figures (light and dark variants, Spanish variants on
the Spanish mirrors) where the concept matches the prose: weighting
curves, time integration and the p-p intensity estimator in the signal
analysis page; equal-loudness contours, the specific-loudness pattern
and the hearing-threshold panels in perception; NC/RC rating, the
Schroeder decay and the ISO 717-1 shifted reference in rooms and
buildings; the Lden profile, ISO 9613-1 absorption and the three sound
power routes in environment and transport; the scattering coefficient
and ISO 11654 rating in materials and surfaces; and the Wk weighting and
the resonator mobility triplet in vibration. Each embed reuses the alt
text of the guide that owns the figure and adds a one-line caption.
Also give the wave-simulation section hub the reading-order paragraph
its siblings already have, linking the closed-form pages the FDTD solver
cross-checks, in both languages.
* Address review findings from the Spanish locale sweeps
Second pass fixes flagged by review: five terminology occurrences the
line-based sweep missed because the noun and adjective were split by a
line wrap or emphasis markup (sound-power, rotorcraft-noise and two
section hubs); six Spanish pages that still embedded the English figure
variant although the _es variant exists (junction-transmission,
aircraft-noise airport contour, miso-coherence,
objective-intelligibility, psychoacoustic-annoyance twice); and 19 more
language="es" arguments on figure-reproduction plot calls the first
pass missed, chained-call receivers such as room.noise_criterion(spl)
.plot() and the axes-creating first call of the two-profile
atmospheric-refraction snippet among them. The lab-insulation plot
wrappers forward keyword arguments to the rating plot, so the three
calls excluded earlier now take the argument too. All Spanish python
fences re-checked to compile and EN/ES parity re-verified.
* Carry the UNE terminology into the generated-asset Spanish strings
Apply the same evidence-based decisions to every Spanish string source
that feeds generated assets: the translation tables of
generate_graphs.py and generate_diagrams.py, the _STRINGS tables of the
plot modules and the report i18n values. 35 strings change: "presión
acústica" (UNE-EN ISO 16283-2:2016, 10052:2005, 3746:2011),
"potencia acústica" (UNE-EN ISO 3746:2011, 4871:2010, 9614-1:2010),
"intensidad acústica" (UNE-EN 61043:1999, 9614-1:2010), "absorción
acústica" (UNE-EN ISO 3746:2011) and "nivel de presión acústica de
impactos" (UNE-EN ISO 12354-2:2018). Strings the UNE editions keep are
untouched: "emisión sonora", "exposición sonora", "campo sonoro",
"fuente sonora". Only Spanish values change; the English keys stay.
The two plot-i18n test assertions that pin the axis label follow, and
the eight Spanish doc fences that deliberately mirrored the old figure
labels now mirror the new ones.
* Regenerate the Spanish figure variants with the UNE terminology
make graphs after the string-source change: 48 files, all of them _es
or _es_dark variants (24 figure/diagram pairs), picking up "presión
acústica", "potencia acústica", "intensidad acústica", "absorción
acústica" and "nivel de presión acústica de impactos" in titles and
axis labels. The English variants are untouched. The committed example
fiches need no regeneration: every example in generate_reports.py
renders in English, so no changed Spanish report string reaches them.
* Align the intensity-fiche Spanish assertions with the UNE terminology
Base the whole-body A(8) on the Directive 2002/44/EC Part B dominant axis and tighten the vibration fiches (#352)
Directive 2002/44/EC bases the whole-body daily exposure A(8) on the
highest of the frequency-weighted axis values 1,4*a_wx, 1,4*a_wy, a_wz
(Annex, Part B, point 1), not on the ISO 2631-1 Eq. (10) vector total
a_v; the hand-arm side keeps the Part A vector total a_hv.
- Relabel the whole-body magnitude of the daily-exposure fiche as
a_w,max with a printed note stating the Part B basis (EN/ES); add
vibration.wbv_exposure_basis() returning the dominant-axis value and
document in daily_vibration_exposure which magnitude each kind must
be fed with; state the same basis in the human-vibration guide
(EN/ES) and the measurement-chain diagram.
- Derive the boxed exposure zone of the fiche from the same
displayed-rounded comparisons as the assessment rows and the verdict,
so an A(8) printing exactly at a threshold cannot show a zone one
step below its own Exceeded row.
- ISO 10848 Kij fiche: distinguish an empty single-number mean caused
by every in-range band being bracketed (M < 0,25) from a spectrum
with no bands in the Annex A range (EN/ES).
- Spanish ISO 2631-5 outputs: translate the subject sex in the
injury-probability plot title and the word Formula in the fiche's
clause references.
- Correct the running_rms comment: the linear window divides by the
full window length (zero-padded front), it does not average over the